HVR

Reliable three phase compensation servo motor technology, suitable for 100% unbalanced load, full protection design providing 100% stabilization & security for diverse applications such as Multi-color printing machines, Air compressors, CNC machines, Punching machines, Laser cutting machines and Welding machines.


Best Suited for: Banking, financial and insurance, data center, education, healthcare, government.


DOCUMENTS & DOWNLOADS

DOCUMENTS & DOWNLOADS

DOCUMENTS & DOWNLOADS

Description
  • Three phase compensation servo motor technology Wide input voltage range 276-450V (260-430V optional) Rated output voltage: 380V (400/415V optional) 100% unbalanced loading capability +/-3% output precision (+/-1% optional) Selectable 6s/180s output delay Industrial strength components with extremely long time lifespan * Optional
  • High efficiency Isolated manual bypass switch Output low-voltage / high-voltage protection Open-phase protection Overload and short circuit protection High temperature protection Surge/spike protection (replaceable SPD)* Digital display for voltage and current RS232/RS485 communication ports *

 * Optional Features

DOCUMENTS & DOWNLOADS

SPECIFICATION

ModelHVR 10K
 
Input 
Rating
Rated Input Voltage
Input Voltage Range
Input Frequency
Power Factor
10kVA
380V (400V/415V Optional)
276-450V
45-65Hz
0.98
 
Ouput 
Output Power
Rated Output Voltage
Output Precision
Response Time
Efficiency
6kW
380V (400V/415V Optional)
±3% (±1% Optional)
<1s, against 10% variation of input voltage
>96%
 
Protection 
Output Under Voltage
Output Over Voltage
Overload
Overheat
Phase Failure
Wrong Phase Sequence
Short Circuit
Bypass
Output Delay Time
Surge Spike
RS232/RS485
Output cutoff by contactor + "L" in display + Buzzer beeping
Output cutoff by contactor + "H" in display + Buzzer beeping
Output cutoff by contactor + "F" in display + Buzzer beeping
Output cutoff by contactor + "C" in display + Buzzer beeping
Output cutoff by contactor + Buzzer beeping
Can't switch on regulator
Input cutoff by air breaker
Isolated Manual Bypass Switch (Automatic Bypass Optional)
6s/180s Selectable
Optional, Replaceable SPD
Optional
 
Digital Display 
Input Voltage
Output Voltage
Output Current
Line Voltage: AB, BC, CA Phase Voltage: A, B, C
Line Voltage: AB, BC, CA Phase Voltage: A, B, C
Phase Current: A, B, C
 
Safety 
Insulation Voltage
Insulation Resistance
Creepage Distance
Grounding Resistance
Insulation Class of Coil
Cooling Mode
IP Level
Audible Noise
2,000V / 60s
>5MΩ
>8mm
<0.1MΩ
Class F (155°C)
Cooling Fan
IP20
<65dB at 1m distance with full load
 
Operating
Conditions
 
Operating Temperature
Operating Humidity
Operating Altitude
-5°C - +45°C
10%-90%, non-condesing
<1,000m
 
Physical 
Machine Size
N.W.
Packing Size
G.W.
D520 x W460 x H830 mm
70kgs
D530 x W470 x H850 mm
80kgs
ModelHVR 15K
 
Input 
Rating
Rated Input Voltage
Input Voltage Range
Input Frequency
Power Factor
15kVA
380V (400V/415V Optional)
276-450V
45-65Hz
0.98
 
Ouput 
Output Power
Rated Output Voltage
Output Precision
Response Time
Efficiency
9kW
380V (400V/415V Optional)
±3% (±1% Optional)
<1s, against 10% variation of input voltage
>96%
 
Protection 
Output Under Voltage
Output Over Voltage
Overload
Overheat
Phase Failure
Wrong Phase Sequence
Short Circuit
Bypass
Output Delay Time
Surge Spike
RS232/RS485
Output cutoff by contactor + "L" in display + Buzzer beeping
Output cutoff by contactor + "H" in display + Buzzer beeping
Output cutoff by contactor + "F" in display + Buzzer beeping
Output cutoff by contactor + "C" in display + Buzzer beeping
Output cutoff by contactor + Buzzer beeping
Can't switch on regulator
Input cutoff by air breaker
Isolated Manual Bypass Switch (Automatic Bypass Optional)
6s/180s Selectable
Optional, Replaceable SPD
Optional
 
Digital Display 
Input Voltage
Output Voltage
Output Current
Line Voltage: AB, BC, CA Phase Voltage: A, B, C
Line Voltage: AB, BC, CA Phase Voltage: A, B, C
Phase Current: A, B, C
 
Safety 
Insulation Voltage
Insulation Resistance
Creepage Distance
Grounding Resistance
Insulation Class of Coil
Cooling Mode
IP Level
Audible Noise
2,000V / 60s
>5MΩ
>8mm
<0.1MΩ
Class F (155°C)
Cooling Fan
IP20
<65dB at 1m distance with full load
 
Operating
Conditions
 
Operating Temperature
Operating Humidity
Operating Altitude
-5°C - +45°C
10%-90%, non-condesing
<1,000m
 
Physical 
Machine Size
N.W.
Packing Size
G.W.
D520 x W460 x H830 mm
78kgs
D530 x W470 x H850 mm
88kgs
ModelHVR 15K
 
Input 
Rating
Rated Input Voltage
Input Voltage Range
Input Frequency
Power Factor
15kVA
380V (400V/415V Optional)
276-450V
45-65Hz
0.98
 
Ouput 
Output Power
Rated Output Voltage
Output Precision
Response Time
Efficiency
9kW
380V (400V/415V Optional)
±3% (±1% Optional)
<1s, against 10% variation of input voltage
>96%
 
Protection 
Output Under Voltage
Output Over Voltage
Overload
Overheat
Phase Failure
Wrong Phase Sequence
Short Circuit
Bypass
Output Delay Time
Surge Spike
RS232/RS485
Output cutoff by contactor + "L" in display + Buzzer beeping
Output cutoff by contactor + "H" in display + Buzzer beeping
Output cutoff by contactor + "F" in display + Buzzer beeping
Output cutoff by contactor + "C" in display + Buzzer beeping
Output cutoff by contactor + Buzzer beeping
Can't switch on regulator
Input cutoff by air breaker
Isolated Manual Bypass Switch (Automatic Bypass Optional)
6s/180s Selectable
Optional, Replaceable SPD
Optional
 
Digital Display 
Input Voltage
Output Voltage
Output Current
Line Voltage: AB, BC, CA Phase Voltage: A, B, C
Line Voltage: AB, BC, CA Phase Voltage: A, B, C
Phase Current: A, B, C
 
Safety 
Insulation Voltage
Insulation Resistance
Creepage Distance
Grounding Resistance
Insulation Class of Coil
Cooling Mode
IP Level
Audible Noise
2,000V / 60s
>5MΩ
>8mm
<0.1MΩ
Class F (155°C)
Cooling Fan
IP20
<65dB at 1m distance with full load
 
Operating
Conditions
 
Operating Temperature
Operating Humidity
Operating Altitude
-5°C - +45°C
10%-90%, non-condesing
<1,000m
 
Physical 
Machine Size
N.W.
Packing Size
G.W.
D520 x W460 x H830 mm
78kgs
D530 x W470 x H850 mm
88kgs
ModelHVR 30K
 
Input 
Rating
Rated Input Voltage
Input Voltage Range
Input Frequency
Power Factor
30kVA
380V (400V/415V Optional)
276-450V
45-65Hz
0.98
 
Ouput 
Output Power
Rated Output Voltage
Output Precision
Response Time
Efficiency
18kW
380V (400V/415V Optional)
±3% (±1% Optional)
<1s, against 10% variation of input voltage
>96%
 
Protection 
Output Under Voltage
Output Over Voltage
Overload
Overheat
Phase Failure
Wrong Phase Sequence
Short Circuit
Bypass
Output Delay Time
Surge Spike
RS232/RS485
Output cutoff by contactor + "L" in display + Buzzer beeping
Output cutoff by contactor + "H" in display + Buzzer beeping
Output cutoff by contactor + "F" in display + Buzzer beeping
Output cutoff by contactor + "C" in display + Buzzer beeping
Output cutoff by contactor + Buzzer beeping
Can't switch on regulator
Input cutoff by air breaker
Isolated Manual Bypass Switch (Automatic Bypass Optional)
6s/180s Selectable
Optional, Replaceable SPD
Optional
 
Digital Display 
Input Voltage
Output Voltage
Output Current
Line Voltage: AB, BC, CA Phase Voltage: A, B, C
Line Voltage: AB, BC, CA Phase Voltage: A, B, C
Phase Current: A, B, C
 
Safety 
Insulation Voltage
Insulation Resistance
Creepage Distance
Grounding Resistance
Insulation Class of Coil
Cooling Mode
IP Level
Audible Noise
2,000V / 60s
>5MΩ
>8mm
<0.1MΩ
Class F (155°C)
Cooling Fan
IP20
<65dB at 1m distance with full load
 
Operating
Conditions
 
Operating Temperature
Operating Humidity
Operating Altitude
-5°C - +45°C
10%-90%, non-condesing
<1,000m
 
Physical 
Machine Size
N.W.
Packing Size
G.W.
D520 x W460 x H830 mm
108kgs
D530 x W470 x H850 mm
118kgs
ModelHVR 45K
 
Input 
Rating
Rated Input Voltage
Input Voltage Range
Input Frequency
Power Factor
45kVA
380V (400V/415V Optional)
276-450V
45-65Hz
0.98
 
Ouput 
Output Power
Rated Output Voltage
Output Precision
Response Time
Efficiency
36kW
380V (400V/415V Optional)
±3% (±1% Optional)
<1s, against 10% variation of input voltage
>96%
 
Protection 
Output Under Voltage
Output Over Voltage
Overload
Overheat
Phase Failure
Wrong Phase Sequence
Short Circuit
Bypass
Output Delay Time
Surge Spike
RS232/RS485
Output cutoff by contactor + "L" in display + Buzzer beeping
Output cutoff by contactor + "H" in display + Buzzer beeping
Output cutoff by contactor + "F" in display + Buzzer beeping
Output cutoff by contactor + "C" in display + Buzzer beeping
Output cutoff by contactor + Buzzer beeping
Can't switch on regulator
Input cutoff by air breaker
Isolated Manual Bypass Switch (Automatic Bypass Optional)
6s/180s Selectable
Optional, Replaceable SPD
Optional
 
Digital Display 
Input Voltage
Output Voltage
Output Current
Line Voltage: AB, BC, CA Phase Voltage: A, B, C
Line Voltage: AB, BC, CA Phase Voltage: A, B, C
Phase Current: A, B, C
 
Safety 
Insulation Voltage
Insulation Resistance
Creepage Distance
Grounding Resistance
Insulation Class of Coil
Cooling Mode
IP Level
Audible Noise
2,000V / 60s
>5MΩ
>8mm
<0.1MΩ
Class F (155°C)
Cooling Fan
IP20
<65dB at 1m distance with full load
 
Operating
Conditions
 
Operating Temperature
Operating Humidity
Operating Altitude
-5°C - +45°C
10%-90%, non-condesing
<1,000m
 
Physical 
Machine Size
N.W.
Packing Size
G.W.
D600 x W520 x H1080 mm
175kgs
D610 x W530 x H1200 mm
190kgs
ModelHVR 60K
 
Input 
Rating
Rated Input Voltage
Input Voltage Range
Input Frequency
Power Factor
60kVA
380V (400V/415V Optional)
276-450V
45-65Hz
0.98
 
Ouput 
Output Power
Rated Output Voltage
Output Precision
Response Time
Efficiency
48kW
380V (400V/415V Optional)
±3% (±1% Optional)
<1s, against 10% variation of input voltage
>96%
 
Protection 
Output Under Voltage
Output Over Voltage
Overload
Overheat
Phase Failure
Wrong Phase Sequence
Short Circuit
Bypass
Output Delay Time
Surge Spike
RS232/RS485
Output cutoff by contactor + "L" in display + Buzzer beeping
Output cutoff by contactor + "H" in display + Buzzer beeping
Output cutoff by contactor + "F" in display + Buzzer beeping
Output cutoff by contactor + "C" in display + Buzzer beeping
Output cutoff by contactor + Buzzer beeping
Can't switch on regulator
Input cutoff by air breaker
Isolated Manual Bypass Switch (Automatic Bypass Optional)
6s/180s Selectable
Optional, Replaceable SPD
Optional
 
Digital Display 
Input Voltage
Output Voltage
Output Current
Line Voltage: AB, BC, CA Phase Voltage: A, B, C
Line Voltage: AB, BC, CA Phase Voltage: A, B, C
Phase Current: A, B, C
 
Safety 
Insulation Voltage
Insulation Resistance
Creepage Distance
Grounding Resistance
Insulation Class of Coil
Cooling Mode
IP Level
Audible Noise
2,000V / 60s
>5MΩ
>8mm
<0.1MΩ
Class F (155°C)
Cooling Fan
IP20
<65dB at 1m distance with full load
 
Operating
Conditions
 
Operating Temperature
Operating Humidity
Operating Altitude
-5°C - +45°C
10%-90%, non-condesing
<1,000m
 
Physical 
Machine Size
N.W.
Packing Size
G.W.
D600 x W520 x H1080 mm
190kgs
D610 x W530 x H1200 mm
205kgs
ModelHVR 80K
 
Input 
Rating
Rated Input Voltage
Input Voltage Range
Input Frequency
Power Factor
80kVA
380V (400V/415V Optional)
276-450V
45-65Hz
0.98
 
Ouput 
Output Power
Rated Output Voltage
Output Precision
Response Time
Efficiency
64kW
380V (400V/415V Optional)
±3% (±1% Optional)
<1s, against 10% variation of input voltage
>96%
 
Protection 
Output Under Voltage
Output Over Voltage
Overload
Overheat
Phase Failure
Wrong Phase Sequence
Short Circuit
Bypass
Output Delay Time
Surge Spike
RS232/RS485
Output cutoff by contactor + "L" in display + Buzzer beeping
Output cutoff by contactor + "H" in display + Buzzer beeping
Output cutoff by contactor + "F" in display + Buzzer beeping
Output cutoff by contactor + "C" in display + Buzzer beeping
Output cutoff by contactor + Buzzer beeping
Can't switch on regulator
Input cutoff by air breaker
Isolated Manual Bypass Switch (Automatic Bypass Optional)
6s/180s Selectable
Optional, Replaceable SPD
Optional
 
Digital Display 
Input Voltage
Output Voltage
Output Current
Line Voltage: AB, BC, CA Phase Voltage: A, B, C
Line Voltage: AB, BC, CA Phase Voltage: A, B, C
Phase Current: A, B, C
 
Safety 
Insulation Voltage
Insulation Resistance
Creepage Distance
Grounding Resistance
Insulation Class of Coil
Cooling Mode
IP Level
Audible Noise
2,000V / 60s
>5MΩ
>8mm
<0.1MΩ
Class F (155°C)
Cooling Fan
IP20
<65dB at 1m distance with full load
 
Operating
Conditions
 
Operating Temperature
Operating Humidity
Operating Altitude
-5°C - +45°C
10%-90%, non-condesing
<1,000m
 
Physical 
Machine Size
N.W.
Packing Size
G.W.
D600 x W570 x H1080 mm
210kgs
D610 x W580 x H1200 mm
228kgs
ModelHVR 100K
 
Input 
Rating
Rated Input Voltage
Input Voltage Range
Input Frequency
Power Factor
100kVA
380V (400V/415V Optional)
276-450V
45-65Hz
0.98
 
Ouput 
Output Power
Rated Output Voltage
Output Precision
Response Time
Efficiency
80kW
380V (400V/415V Optional)
±3% (±1% Optional)
<1s, against 10% variation of input voltage
>96%
 
Protection 
Output Under Voltage
Output Over Voltage
Overload
Overheat
Phase Failure
Wrong Phase Sequence
Short Circuit
Bypass
Output Delay Time
Surge Spike
RS232/RS485
Output cutoff by contactor + "L" in display + Buzzer beeping
Output cutoff by contactor + "H" in display + Buzzer beeping
Output cutoff by contactor + "F" in display + Buzzer beeping
Output cutoff by contactor + "C" in display + Buzzer beeping
Output cutoff by contactor + Buzzer beeping
Can't switch on regulator
Input cutoff by air breaker
Isolated Manual Bypass Switch (Automatic Bypass Optional)
6s/180s Selectable
Optional, Replaceable SPD
Optional
 
Digital Display 
Input Voltage
Output Voltage
Output Current
Line Voltage: AB, BC, CA Phase Voltage: A, B, C
Line Voltage: AB, BC, CA Phase Voltage: A, B, C
Phase Current: A, B, C
 
Safety 
Insulation Voltage
Insulation Resistance
Creepage Distance
Grounding Resistance
Insulation Class of Coil
Cooling Mode
IP Level
Audible Noise
2,000V / 60s
>5MΩ
>8mm
<0.1MΩ
Class F (155°C)
Cooling Fan
IP20
<65dB at 1m distance with full load
 
Operating
Conditions
 
Operating Temperature
Operating Humidity
Operating Altitude
-5°C - +45°C
10%-90%, non-condesing
<1,000m
 
Physical 
Machine Size
N.W.
Packing Size
G.W.
D600 x W570 x H1080 mm
235kgs
D610 x W580 x H1200 mm
253kgs