Tubular 12 200~250

The Tubular 12V 200~250Ah is manufactured with particular tubular positive high pressure diecasted plates, & designed for longer battery life. It has exceptional eco-friendly Aqua Trap vent plugs which abstain any acid fumes. It is swell-resistant and has no chance of explosion or overcharging, & has sustained and long-lasting life as they have less corrosion.

PCE tubular batteries have splendid features like High Acid Volume per Ampere hour, quick charge acceptance, and plate designed with special additives to get quick recovery from deep discharge.


Best Suited for: Banking, financial and insurance, data center, education, healthcare, government.


DOCUMENTS & DOWNLOADS

DOCUMENTS & DOWNLOADS

DOCUMENTS & DOWNLOADS

Description
  • High antimony lead alloy for improved lifetime and cycling ability
  • Up to 40% more cyclic life than general models
  • Maintenance Free Operation
  • AGM technology for efficient gas recombination
  • Leak proof/Spill proof
  • Can be mounted in any orientation
  • Excellent performance on 1-5 hours of large current discharge
  • Safety valve to prevent out-gassing
  • High reliability and quality
  • Exceptional deep discharge recovery performance
  • Low self discharge characteristic
  • ISO and UL certified

 * Optional Features

DOCUMENTS & DOWNLOADS

SPECIFICATION

ModelPCD12-180D 12V-18.0Ah
 
 
Performance Characteristics 
Cells per unit
Voltage per unit
Design Life
Capacity
Weight
Max. Discharge Current
Internal Resistance
 
Operation Temperature Range
Discharge
Charge
Storage
 
Normal Operating Temperature Range
Float charging Voltage
Recommended Maximum Charging Current Limit
Equalization and Cycle Service
Self Discharge
Terminal
Constainer Material
6
12
12 years
18.0Ah@20hr-rate to 1.75V per cell @25°C
Approx. 5.3 Kg
150 A (5 sec)
Approx. 17mΩ
 
 
-20°C~60°C
0°C~50°C
-20°C~60°C
 
25°C±5°C
13.6 to 13.8 VDC/unit Average at 25°C
4.5 A
14.4 to 15.0 VDC/unit Average at 25°C
PCE batteries can be stored for more than 6 months at 25°C. Please charge batteries before using. For higher temperature, the time interval will be shorter.
Faston F3/F13
A.B.S. (UL94-HB), Flammability resistance of UL94-V1 can be available upon request.
 
 
Charging Procedures (12V series)Charging Procedures (6V series)
Application
Charge Voltage(V)
TemperatureSet pointAllowable range
25°C14.714.4~15.0
25°C13.713.6~13.8
Max. Charge

Current
Cycle Use0.3C
Standby0.3C
Application
Charge Voltage(V)
TemperatureSet pointAllowable range
25°C7.357.25~7.45
25°C6.856.8~6.9
Max. Charge

Current
Cycle Use0.3C
Standby0.3C
  
 
Discharge Current VS. Discharge VoltageCharge the batteries at least once every six months,

if they are stored at 25°C
Final Discharge

Voltage V/cell
1.75V1.70V1.60V
Discharge

Current (A)
(A) ≤0.2C0.2C< (A) <1.0C(A) ≥1.0C
Charging Method: 
Constant Voltage-0.2Cx2h+14.4~15.0V, 24h, Max. Current 0.3CA
Constant Current-0.2Cx2h+0.1CAx12h
Fast-0.2Cx2h+0.3CAx4h
 
 
Constant Current Discharge Characteristics Unit: A (25°C)
F.V/Time 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h
 
1.60V

1.67V

1.70V

1.75V

1.80V

1.85V
 74.7

69.9

66.2

59.8

53.4

47.0
 50.0

46.6

45.2

42.3

39.4

36.5
 38.4

36.1

35.3

33.4

31.6

29.7
 21.1

20.8

20.6

20.2

19.7

19.2
 12.5

12.4

12.3

12.2

12.0

11.8
 7.49

7.43

7.42

7.33

7.20

7.09
 4.61

4.59

4.57

4.55

4.52

4.48
 3.78

3.76

3.74

3.73

3.71

3.69
 3.04

3.02

3.01

2.99

2.97

2.95
 2.23

2.23

2.23

2.23

2.21

2.21
 1.76

1.75

1.73

1.71

1.67

1.66
 0.99

0.95

0.94

0.90

0.86

0.85
 
 
 
Constant Power Discharge Characteristics Unit: W (25°C)
F.V/Time 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h
 
1.60V

1.67V

1.70V

1.75V

1.80V

1.85V
 144

135

132

120

107

94.1
 93.6

90.0

87.3

83.7

78.3

72.9
 76.1

72.2

70.5

66.8

63.1

59.5
 42.2

41.5

41.3

40.3

39.3

38.4
 25.0

24.9

24.8

24.4

24.0

23.6
 15.0

14.9

14.8

14.6

14.4

14.2
 9.20

9.18

9.16

9.11

9.04

8.96
 7.52

7.51

7.51

7.45

7.40

7.34
 7.15

7.09

7.07

7.06

7.04

7.02
 4.48

4.48

4.45

4.43

4.41

4.41
 3.51

3.47

3.44

3.40

3.35

3.29
 1.96

1.89

1.85

1.78

1.73

1.67
 
 
 
 
 
ModelPCD12-260D 12V-26.0Ah
 
 
Performance Characteristics 
Cells per unit
Voltage per unit
Design Life
Capacity
Weight
Max. Discharge Current
Internal Resistance
 
Operation Temperature Range
Discharge
Charge
Storage
 
Normal Operating Temperature Range
Float charging Voltage
Recommended Maximum Charging Current Limit
Equalization and Cycle Service
Self Discharge
Terminal
Constainer Material
6
12
12 years
26.0Ah@20hr-rate to 1.75V per cell @25°C
Approx. 9.2 Kg
260 A (5 sec)
Approx. 10mΩ
 
 
-20°C~60°C
0°C~50°C
-20°C~60°C
 
25°C±5°C
13.6 to 13.8 VDC/unit Average at 25°C
7.8 A
14.4 to 15.0 VDC/unit Average at 25°C
PCE batteries can be stored for more than 6 months at 25°C. Please charge batteries before using. For higher temperature, the time interval will be shorter.
Faston F3/F13
A.B.S. (UL94-HB), Flammability resistance of UL94-V1 can be available upon request.
 
 
Charging Procedures (12V series)Charging Procedures (6V series)
Application
Charge Voltage(V)
TemperatureSet pointAllowable range
25°C14.714.4~15.0
25°C13.713.6~13.8
Max. Charge

Current
Cycle Use0.3C
Standby0.3C
Application
Charge Voltage(V)
TemperatureSet pointAllowable range
25°C7.357.25~7.45
25°C6.856.8~6.9
Max. Charge

Current
Cycle Use0.3C
Standby0.3C
  
 
Discharge Current VS. Discharge VoltageCharge the batteries at least once every six months,

if they are stored at 25°C
Final Discharge

Voltage V/cell
1.75V1.70V1.60V
Discharge

Current (A)
(A) ≤0.2C0.2C< (A) <1.0C(A) ≥1.0C
Charging Method: 
Constant Voltage-0.2Cx2h+14.4~15.0V, 24h, Max. Current 0.3CA
Constant Current-0.2Cx2h+0.1CAx12h
Fast-0.2Cx2h+0.3CAx4h
 
 
Constant Current Discharge Characteristics Unit: A (25°C)
F.V/Time 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h
 
1.60V

1.67V

1.70V

1.75V

1.80V

1.85V
 116

109

103

93.0

83.0

73.2
 77.7

72.5

70.3

65.7

61.3

56.8
 59.7

56.1

54.9

52.0

49.1

46.3
 32.8

32.3

32.1

31.4

30.6

29.8
 19.4

19.3

19.2

18.9

18.6

18.4
 11.6

11.6

11.5

11.4

11.2

11.0
 7.17

7.14

7.11

7.08

7.03

6.97
 5.88

5.85

5.82

5.80

5.77

5.74
 4.73

4.70

4.68

4.65

4.62

4.59
 3.47

3.47

3.47

3.47

3.44

3.44
 2.74

2.72

2.69

2.66

2.60

2.58
 1.54

1.48

1.46

1.40

1.34

1.32
 
 
 
Constant Power Discharge Characteristics Unit: W (25°C)
F.V/Time 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h
 
1.60V

1.67V

1.70V

1.75V

1.80V

1.85V
 224

210

206

186

166

146
 146

140

136

130

122

113
 118

112

110

104

98

93
 65.7

64.6

64.2

62.7

61.2

59.7
 38.8

38.7

38.6

38.0

37.4

36.7
 23.3

23.1

23.1

22.7

22.4

22.1
 14.3

14.3

14.3

14.2

14.1

13.9
 11.7

11.7

11.7

11.6

11.5

11.4
 11.1

11.0

11.0

11.0

10.9

10.9
 6.97

6.97

6.92

6.89

6.86

6.86
 5.46

5.40

5.35

5.29

5.21

5.12
 3.05

2.94

2.88

2.77

2.69

2.60
 
 
 
 
 
ModelPCD12-40D 12V-40Ah
 
 
Performance Characteristics 
Cells per unit
Voltage per unit
Design Life
Capacity
Weight
Max. Discharge Current
Internal Resistance
 
Operation Temperature Range
Discharge
Charge
Storage
 
Normal Operating Temperature Range
Float charging Voltage
Recommended Maximum Charging Current Limit
Equalization and Cycle Service
Self Discharge
Terminal
Constainer Material
6
12
10 years
40Ah@10hr-rate to 1.75V per cell @25°C
Approx. 13.5 Kg
200 A (5 sec)
Approx. 8mΩ
 
 
-20~60°C
0°C~50°C
-20°C~60°C
 
25°C±5°C
13.6 to 13.8 VDC/unit Average at 25°C
12.0 A
14.4 to 15.0 VDC/unit Average at 25°C
PCE batteries can be stored for more than 6 months at 25°C. Please charge batteries before using. For higher temperature, the time interval will be shorter.
Terminal F4/F11
A.B.S. (UL94-HB), Flammability resistance of UL94-V1 can be available upon request.
 
 
Charging Procedures (12V series)Charging Procedures (6V series)
Application
Charge Voltage(V)
TemperatureSet pointAllowable range
25°C14.714.4~15.0
25°C13.713.6~13.8
Max. Charge
Current
Cycle Use0.3C
Standby0.3C
Application
Charge Voltage(V)
TemperatureSet pointAllowable range
25°C7.357.25~7.45
25°C6.856.8~6.9
Max. Charge
Current
Cycle Use0.3C
Standby0.3C
  
 
Discharge Current VS. Discharge VoltageCharge the batteries at least once every six months,
if they are stored at 25°C
Final Discharge
Voltage V/cell
1.75V1.70V1.60V
Discharge
Current (A)
(A) ≤0.2C0.2C< (A) <1.0C(A) ≥1.0Cs
Charging Method: 
Constant Voltage-0.2Cx2h+14.4~15.0V, 24h, Max. Current 0.3CA
Constant Current-0.2Cx2h+0.1CAx12h
Fast-0.2Cx2h+0.3CAx4h
 
 
Constant Current Discharge Characteristics Unit: A (25°C)
F.V/Time 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h
 
1.60V
1.67V
1.70V
1.75V
1.80V
1.85V
 150
146
137
123
111
97
 107
102
98
91
83
74
 78
76
75
72
66
59
 46
45
45
44
42
39
 26.0
25.9
25.6
25.4
24.8
23.6
 16.0
15.8
15.7
15.6
15.3
14.6
 10.4
10.4
10.3
10.3
10.0
9.6
 8.6
8.6
8.6
8.5
8.3
7.9
 6.8
6.8
6.7
6.6
6.5
6.2
 4.9
4.9
4.8
4.8
4.7
4.5
 4.2
4.1
4.1
4.0
4.0
3.9
 2.2
2.2
2.1
2.1
2.0
1.9
 
 
 
Constant Power Discharge Characteristics Unit: W (25°C)
F.V/Time 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h
 
1.60V
1.67V
1.70V
1.75V
1.80V
1.85V
 268
263
248
223
201
173
 196
187
181
167
152
135
 144
141
139
133
122
109
 87
85
84
83
79
74
 49.6
49.3
49.0
48.5
47.3
44.8
 30.6
30.5
30.2
29.9
29.5
28.1
 20.1
20.0
19.9
19.8
19.3
18.4
 16.6
16.6
16.5
16.4
16.0
15.2
 13.1
13.0
13.0
12.9
12.7
12.0
 9.5
9.5
9.4
9.3
9.1
8.8
 7.8
7.7
7.7
7.6
7.5
7.3
 4.1
4.1
4.0
4.0
4.0
3.8
 
 
 
 
 
ModelPCD12-65D 12V-65Ah
 
 
Performance Characteristics 
Cells per unit
Voltage per unit
Design Life
Capacity
Weight
Max. Discharge Current
Internal Resistance
 
Operation Temperature Range
Discharge
Charge
Storage
 
Normal Operating Temperature Range
Float charging Voltage
Recommended Maximum Charging Current Limit
Equalization and Cycle Service
Self Discharge
Terminal
Constainer Material
6
12
10 years
65Ah@10hr-rate to 1.75V per cell @25°C
Approx. 22.2 Kg
325 A (5 sec)
Approx. 6mΩ
 
 
-20~60°C
0°C~50°C
-20°C~60°C
 
25°C±5°C
13.6 to 13.8 VDC/unit Average at 25°C
19.5 A
14.4 to 15.0 VDC/unit Average at 25°C
PCE batteries can be stored for more than 6 months at 25°C. Please charge batteries before using. For higher temperature, the time interval will be shorter.
Terminal F5/F11
A.B.S. (UL94-HB), Flammability resistance of UL94-V1 can be available upon request.
 
 
Charging Procedures (12V series)Charging Procedures (6V series)
Application
Charge Voltage(V)
TemperatureSet pointAllowable range
25°C14.714.4~15.0
25°C13.713.6~13.8
Max. Charge

Current
Cycle Use0.3C
Standby0.3C
Application
Charge Voltage(V)
TemperatureSet pointAllowable range
25°C7.357.25~7.45
25°C6.856.8~6.9
Max. Charge

Current
Cycle Use0.3C
Standby0.3C
  
 
Discharge Current VS. Discharge VoltageCharge the batteries at least once every six months,

if they are stored at 25°C
Final Discharge

Voltage V/cell
1.75V1.70V1.60V
Discharge

Current (A)
(A) ≤0.2C0.2C< (A) <1.0C(A) ≥1.0C
Charging Method: 
Constant Voltage-0.2Cx2h+14.4~15.0V, 24h, Max. Current 0.3CA
Constant Current-0.2Cx2h+0.1CAx12h
Fast-0.2Cx2h+0.3CAx4h
 
 
Constant Current Discharge Characteristics Unit: A (25°C)
F.V/Time 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h
 
1.60V

1.67V

1.70V

1.75V

1.80V

1.85V
 243

237

223

200

181

157
 174

166

160

148

135

120
 127

124

122

116

107

96
 75

74

73

71

68

64
 42.3

42.1

41.7

41.3

40.3

38.3
 25.9

25.7

25.5

25.4

24.9

23.8
 17.0

16.9

16.8

16.7

16.3

15.5
 14.0

14.0

13.9

13.8

13.5

12.8
 11.1

11.0

10.9

10.8

10.6

10.1
 8.0

7.9

7.9

7.8

7.7

7.3
 6.8

6.7

6.6

6.6

6.5

6.3
 3.6

3.5

3.4

3.4

3.3

3.1
 
 
 
Constant Power Discharge Characteristics Unit: W (25°C)
F.V/Time 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h
 
1.60V

1.67V

1.70V

1.75V

1.80V

1.85V
 436

427

403

363

326

282
 319

304

294

272

247

219
 235

230

227

216

199

177
 141

139

137

134

128

120
 80.5

80.1

79.6

78.8

76.8

72.8
 49.7

49.5

49.1

48.6

47.9

45.7
 32.6

32.6

32.4

32.2

31.4

29.8
 27.0

27.0

26.8

26.7

25.9

24.7
 21.3

21.2

21.1

20.9

20.6

19.6
 15.5

15.4

15.3

15.1

14.8

14.3
 12.7

12.5

12.5

12.4

12.2

11.8
 6.7

6.6

6.6

6.5

6.4

6.2
 
 
 
 
 
ModelPCD12-100D 12V-100Ah
 
 
Performance Characteristics 
Cells per unit
Voltage per unit
Design Life
Capacity
Weight
Max. Discharge Current
Internal Resistance
 
Operation Temperature Range
Discharge
Charge
Storage
 
Normal Operating Temperature Range
Float charging Voltage
Recommended Maximum Charging Current Limit
Equalization and Cycle Service
Self Discharge
Terminal
Constainer Material
6
12
10 years
100Ah@10hr-rate to 1.75V per cell @25°C
Approx. 30 Kg
500 A (5 sec)
Approx. 5mΩ
 
 
-20~60°C
0°C~50°C
-20°C~60°C
 
25°C±5°C
13.6 to 13.8 VDC/unit Average at 25°C
30 A
14.4 to 15.0 VDC/unit Average at 25°C
PCE batteries can be stored for more than 6 months at 25°C. Please charge batteries before using. For higher temperature, the time interval will be shorter.
Terminal F5/F12
A.B.S. (UL94-HB), Flammability resistance of UL94-V1 can be available upon request.
 
 
Charging Procedures (12V series)Charging Procedures (6V series)
Application
Charge Voltage(V)
TemperatureSet pointAllowable range
25°C14.714.4~15.0
25°C13.713.6~13.8
Max. Charge

Current
Cycle Use0.3C
Standby0.3C
Application
Charge Voltage(V)
TemperatureSet pointAllowable range
25°C7.357.25~7.45
25°C6.856.8~6.9
Max. Charge

Current
Cycle Use0.3C
Standby0.3C
  
 
Discharge Current VS. Discharge VoltageCharge the batteries at least once every six months,

if they are stored at 25°C
Final Discharge

Voltage V/cell
1.75V1.70V1.60V
Discharge

Current (A)
(A) ≤0.2C0.2C< (A) <1.0C(A) ≥1.0C
Charging Method: 
Constant Voltage-0.2Cx2h+14.4~15.0V, 24h, Max. Current 0.3CA
Constant Current-0.2Cx2h+0.1CAx12h
Fast-0.2Cx2h+0.3CAx4h
 
 
Constant Current Discharge Characteristics Unit: A (25°C)
F.V/Time 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h
 
1.60V

1.67V

1.70V

1.75V

1.80V

1.85V
 374

364

343

308

278

242
 268

255

246

227

207

185
 195

191

188

179

165

148
 115

113

112

109

105

98
 65.0

64.7

64.1

63.5

62.0

58.9
 39.9

39.6

39.3

39.0

38.3

36.6
 26.1

26.0

25.8

25.7

25.0

23.9
 21.6

21.5

21.4

21.2

20.7

19.7
 17.0

16.9

16.8

16.6

16.3

15.6
 12.3

12.2

12.1

12.0

11.8

11.3
 10.4

10.3

10.2

10.1

10.0

9.7
 5.5

5.4

5.3

5.2

5.1

4.8
 
 
 
Constant Power Discharge Characteristics Unit: W (25°C)
F.V/Time 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h
 
1.60V

1.67V

1.70V

1.75V

1.80V

1.85V
 671

657

620

558

502

434
 490

468

453

418

380

337
 361

354

349

333

306

273
 216

214

211

206

197

185
 124

123

122

121

118

112
 76.5

76.2

75.5

74.8

73.7

70.3
 50.2

50.1

49.8

49.5

48.3

45.9
 41.6

41.5

41.3

41.0

39.9

38.0
 32.8

32.6

32.5

32.2

31.7

30.1
 23.8

23.7

23.5

23.3

22.8

22.0
 19.5

19.3

19.2

19.0

18.8

18.2
 10.3

10.2

10.1

10.0

9.9

9.5
 
 
 
ModelPCD12-150D 12V-150Ah
 
 
Performance Characteristics 
Cells per unit
Voltage per unit
Design Life
Capacity
Weight
Max. Discharge Current
Internal Resistance
 
Operation Temperature Range
Discharge
Charge
Storage
 
Normal Operating Temperature Range
Float charging Voltage
Recommended Maximum Charging Current Limit
Equalization and Cycle Service
Self Discharge
Terminal
Constainer Material
6
12
10 years
150Ah@10hr-rate to 1.75V per cell @25°C
Approx. 47.0 Kg
750 A (5 sec)
Approx. 4.0mΩ
 
 
-20°C~60°C
0°C~50°C
-20°C~60°C
 
25°C±5°C
13.6 to 13.8 VDC/unit Average at 25°C
45 A
14.4 to 15.0 VDC/unit Average at 25°C
PCE batteries can be stored for more than 6 months at 25°C. Please charge batteries before using. For higher temperature, the time interval will be shorter.
Terminal F5/F12
A.B.S. (UL94-HB), Flammability resistance of UL94-V1 can be available upon request.
 
 
Charging Procedures (12V series)Charging Procedures (6V series)
Application
Charge Voltage(V)
TemperatureSet pointAllowable range
25°C14.714.4~15.0
25°C13.713.6~13.8
Max. Charge

Current
Cycle Use0.3C
Standby0.3C
Application
Charge Voltage(V)
TemperatureSet pointAllowable range
25°C7.357.25~7.45
25°C6.856.8~6.9
Max. Charge

Current
Cycle Use0.3C
Standby0.3C
  
 
Discharge Current VS. Discharge VoltageCharge the batteries at least once every six months,

if they are stored at 25°C
Final Discharge

Voltage V/cell
1.75V1.70V1.60V
Discharge

Current (A)
(A) ≤0.2C0.2C< (A) <1.0C(A) ≥1.0C
Charging Method: 
Constant Voltage-0.2Cx2h+14.4~15.0V, 24h, Max. Current 0.3CA
Constant Current-0.2Cx2h+0.1CAx12h
Fast-0.2Cx2h+0.3CAx4h
 
 
Constant Current Discharge Characteristics Unit: A (25°C)
F.V/Time 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h
 
1.60V

1.67V

1.70V

1.75V

1.80V

1.85V
 561

546

515

462

417

363
 402

383

369

341

311

278
 293

287

282

269

248

222
 173

170

168

164

157

147
 97.5

97.1

96.2

95.3

93.0

88.4
 59.9

59.4

59.0

58.5

57.5

54.9
 39.2

39.0

38.7

38.6

37.5

35.9
 32.4

32.3

32.1

31.8

31.1

29.6
 25.5

25.4

25.2

24.9

24.5

23.4
 18.5

18.3

18.2

18.0

17.7

17.0
 15.6

15.5

15.3

15.2

15.0

14.6
 8.3

8.1

8.0

7.8

7.7

7.2
 
 
 
Constant Power Discharge Characteristics Unit: W (25°C)
F.V/Time 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h
 
1.60V

1.67V

1.70V

1.75V

1.80V

1.85V
 1006

985

930

837

753

650
 735

702

679

627

570

506
 542

530

523

499

458

409
 324

320

317

309

295

277
 185.9

185.0

183.6

181.8

177.3

168.0
 114.8

114.3

113.3

112.2

110.6

105.5
 75.3

75.2

74.7

74.3

72.5

68.9
 62.4

62.3

62.0

61.5

59.9

57.0
 49.2

48.9

48.8

48.3

47.6

45.2
 35.7

35.6

35.3

35.0

34.2

33.0
 29.3

29.0

28.8

28.5

28.2

27.3
 15.5

15.3

15.2

15.0

14.9

14.3
 
 
 
 
 

related products

ModelPCD12-200D 12V-200Ah
 
 
Performance Characteristics 
Cells per unit
Voltage per unit
Design Life
Capacity
Weight
Max. Discharge Current
Internal Resistance
 
Operation Temperature Range
Discharge
Charge
Storage
 
Normal Operating Temperature Range
Float charging Voltage
Recommended Maximum Charging Current Limit
Equalization and Cycle Service
Self Discharge
Terminal
Constainer Material
6
12
12 years
200Ah@10hr-rate to 1.75V per cell @25°C
Approx. 65 Kg
1000 A (5 sec)
Approx. 4mΩ
 
 
-20°C~60°C
0°C~50°C
-20°C~60°C
 
25°C±5°C
13.6 to 13.8 VDC/unit Average at 25°C
60 A
14.4 to 15.0 VDC/unit Average at 25°C
PCE batteries can be stored for more than 6 months at 25°C. Please charge batteries before using. For higher temperature, the time interval will be shorter.
Faston F16/F12
A.B.S. (UL94-HB), Flammability resistance of UL94-V1 can be available upon request.
 
 
Charging Procedures (12V series)Charging Procedures (6V series)
Application
Charge Voltage(V)
TemperatureSet pointAllowable range
25°C14.714.4~15.0
25°C13.713.6~13.8
Max. Charge

Current
Cycle Use0.3C
Standby0.3C
Application
Charge Voltage(V)
TemperatureSet pointAllowable range
25°C7.357.25~7.45
25°C6.856.8~6.9
Max. Charge

Current
Cycle Use0.3C
Standby0.3C
  
 
Discharge Current VS. Discharge VoltageCharge the batteries at least once every six months,

if they are stored at 25°C
Final Discharge

Voltage V/cell
1.75V1.70V1.60V
Discharge

Current (A)
(A) ≤0.2C0.2C< (A) <1.0C(A) ≥1.0C
Charging Method: 
Constant Voltage-0.2Cx2h+14.4~15.0V, 24h, Max. Current 0.3CA
Constant Current-0.2Cx2h+0.1CAx12h
Fast-0.2Cx2h+0.3CAx4h
 
 
Constant Current Discharge Characteristics Unit: A (25°C)
F.V/Time 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h
 
1.60V

1.67V

1.70V

1.75V

1.80V

1.85V
 748

728

686

616

556

484
 536

510

492

454

414

370
 390

382

376

358

330

296
 230

226

224

219

209

196
 130.0

129.4

128.2

127.0

124.0

117.8
 79.8

79.2

78.6

78.0

76.6

73.2
 52.2

52.0

51.6

51.4

50.0

47.8
 43.2

43.0

42.8

42.4

41.4

39.4
 34.0

33.8

33.6

33.2

32.6

31.2
 24.6

24.4

24.2

24.0

23.6

22.6
 20.8

20.6

20.4

20.2

20.0

19.4
 11.0

10.8

10.6

10.4

10.2

9.6
 
 
 
Constant Power Discharge Characteristics Unit: W (25°C)
F.V/Time 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h
 
1.60V

1.67V

1.70V

1.75V

1.80V

1.85V
 1341

1314

1240

1117

1004

867
 981

937

905

837

760

675
 722

707

697

665

611

546
 433

427

422

413

394

369
 247.8

246.6

244.8

242.4

236.4

224.0
 153.0

152.4

151.0

149.6

147.4

140.6
 100.4

100.2

99.6

99.0

96.6

91.8
 83.2

83.0

82.6

82.0

79.8

76.0
 65.6

65.2

65.0

64.4

63.4

60.2
 47.6

47.4

47.0

46.6

45.6

44.0
 39.0

38.6

38.4

38.0

37.6

36.4
 20.6

20.4

20.2

20.0

19.8

19.0
 
 
 
 
Â