MX31 10~20K

The MX31 UPS is a 3-phase In/1-phase Out online double conversion UPS available from 10kVA to 20kVA with an output power factor 1. It is designed to provide ultimate performance in power protection and redundancy for critical systems requiring high power availability. The MX31 series has USB and RS-232 communication ports as standard, with a built-in intelligent slot for optional protocol converters (e.g. SNMP…)


Best Suited for: Banking, financial and insurance, server rooms, data centers, education, healthcare, government.


DOCUMENTS & DOWNLOADS

DOCUMENTS & DOWNLOADS

DOCUMENTS & DOWNLOADS

Description
  • 3-phase In/1-phase Out
  • True Online Double Conversion Design
  • Pure Sine Wave Output
  • Fully Digitized Microprocessor Control
  • DSP Technology
  • Output Power Factor 1
  • Active Input Power Factor Correction (PFC 0.99)
  • 50/60 Hz Frequency Converter
  • Wide Input Voltage Range
  • Built in Automatic Bypass
  • Generator Compatible
  • N+X Parallel Redundancy Configuration*
  • Emergency Power Off Function (EPO)
  • Cold Start Function (DC Power On)
  • Advanced Battery Management (ABM Technology)
  • Automatic Diagnostics & Battery Check
  • High Overload Capability and Enhanced Short Circuit Protection
  • Eco Mode For Energy Saving
  • Isolation Transformer*
  • Programmable Power Management Outlets
  • Multi-Function LCD Display
  • Software Monitoring and Control
  • Smart RS-232/USB Communication Port
  • SNMP/AS-400 Communication Slots*

 * Optional Features

DOCUMENTS & DOWNLOADS

ModelMX 10K 31
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
10000VA
380V, 400V, 415V (selectable), 3Φ4Wires
40/70 Hz
305-478 VAC @ 100% load 190-520 VAC @ 50% load
>99%
<3%
 
Output 
Output Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
10000W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø2Wires
50/60 Hz +/-0.1%
0 ms
Online double conversion design
Pure Sinewave
≤2% (linear load), ≤5% (non linear load)
3:1
 
Efficiency 
AC Mode
Battery Mode
96%
95%
 
Protection 
Overload Protection
Short Circuit Protection
110% for 10min, 130% for 1min, >130% for 3sec
UPS output cut off immediately using input fuse/circuit breaker protection
 
System Display 
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
Battery number
Back up time(1/2 Load)
12V 9Ah
9 hours to 90% Full capacity
1A
20
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400**
SNMP**
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
W x D x H mm
Net Weight Kgs
250 X 592 x 576
83
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40ºC, 0 to 95% humidity (non-condensing)
<58dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
*When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
** For optional features
***Product specifications are subject to change without further notice
 
 
ModelMX 15K 31
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
15000VA
380V, 400V, 415V (selectable), 3Φ4Wires
40 to 70 Hz
305-478 VAC at 100% load, 190-520 VAC at 50% load
>99%
<3%
 
Output 
Output Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
15000W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø2Wires
50/60 Hz +/-0.1%
0 ms
Online double conversion design
Pure Sinewave
≤2% (linear load), ≤5% (non linear load)
3:1
 
Efficiency 
AC Mode
Battery Mode
96%
95%
 
Protection 
Overload Protection
Short Circuit Protection
110% for 10min, 130% for 1min, >130% for 3sec
UPS output cut off immediately using input fuse/circuit breaker protection
 
System Display 
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
Battery number
Back up time(1/2 Load)
12V 9Ah
9 hours to 90% Full capacity
2A
20 x2 strings
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400**
SNMP**
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
W x D x H mm
Net Weight Kgs
250 x 815 x 826
164
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40ºC, 0 to 95% humidity (non-condensing)
<60dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
*When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
** For optional features
***Product specifications are subject to change without further notice
ModelMX 20K 31
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
20000VA
380V, 400V, 415V (selectable), 3Φ4Wires
40 to 70 Hz
305-478 VAC at 100% load, 190-520 VAC at 50% load
>99%
<3%
 
Output 
Output Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
20000W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø2Wires
50/60 Hz +/-0.1%
0 ms
Online double conversion design
Pure Sinewave
≤2% (linear load), ≤5% (non linear load)
3:1
 
Efficiency 
AC Mode
Battery Mode
96%
95%
 
Protection 
Overload Protection
Short Circuit Protection
110% for 10min, 130% for 1min, >130% for 3sec
UPS output cut off immediately using input fuse/circuit breaker protection
 
System Display 
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
Battery number
Back up time(1/2 Load)
12V 9Ah
9 hours to 90% Full capacity
2A
20 x2 strings
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400**
SNMP**
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
W x D x H mm
Net Weight Kgs
250 x 815 x 826
164
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40ºC, 0 to 95% humidity (non-condensing)
<60dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
*When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
** For optional features
***Product specifications are subject to change without further notice