EX RM Series

The EX RM UPS is a high-performance online double-conversion system (1–10kVA) with a unity power factor for maximum efficiency. Designed for rack-mounted setups, it ensures reliable, continuous power for critical applications. It features USB, RS-232, and an expansion slot supporting SNMP for advanced monitoring. Ideal for data centers, servers, networking, control systems, and surveillance.

Download Leaflet



Description
  • True Online Double Conversion Design
  • Pure Sine Wave Output
  • Fully Digitized Microprocessor Control
  • DSP Technology
  • Output Power Factor 1
  • Active Input Power Factor Correction (PFC 0.99)
  • 50/60 Hz Frequency Converter
  • Wide Input Voltage Range
  • Cold Start Function (DC Power On)
  • Advanced Battery Management (ABM Technology)
  • Automatic Diagnostics & Battery Check
  • High Overload Capability and Enhanced Short Circuit Protection
  • Eco Mode For Energy Saving
  • Isolation Transformer*
  • Programmable Power Management Outlets
  • Multi-Function LCD Display

 * Optional Features

DOCUMENTS & DOWNLOADS

 
 
ModelMX 1k
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
1000VA
220V, 230V, 240V, 1Ø 2Wires
40Hz~70Hz
160-300 VAC at 100% load, 110-300 VAC at 50% load
>99%
≤3%
 
Ouput 
Output Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
1000W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires
50/60 Hz +/-0.1Hz
0 ms
Online double conversion design
Pure Sinewave
≤2% (linear load), ≤4% (non linear load)
3:1
 
Efficiency 
AC Mode
Battery Mode
95%
93%
 
Protection 
Overload Protection
Short Circuit Protection
110% for 10min, 130% for 1min, >130% for 3sec
UPS output cut off immediately using input fuse/circuit breaker protection
 
System Display 
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
DC Voltage
Back up time(1/2 Load)
12V 7Ah
4 hours to 90% capacity
1.5A
36 VDC
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400**
SNMP**
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
Dimension, WxDxH mm
Net Weight Kgs(lbs)
145 X 397 X 220
12.5 (27.5lbs)
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40°C, 20 to 95% humidity (non-condensing)
<50dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 

* NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.

NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.

** For optional features
***Product specifications are subject to change without further notice

 
 
 
 
ModelMX 2k
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
2000VA
220V, 230V, 240V, 1Ø 2Wires
40Hz~70Hz
160-300 VAC at 100% load, 110-300 VAC at 50% load
>99%
≤3%
 
Ouput 
Output Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
2000W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires
50/60 Hz +/-0.1Hz
0 ms
Online double conversion design
Pure Sinewave
≤2% (linear load), ≤4% (non linear load)
3:1
 
Protection 
Overload Protection
Short Circuit Protection
110% for 10min, 130% for 1min, >130% for 3sec
UPS output cut off immediately using input fuse/circuit breaker protection
 
Efficiency 
AC Mode
Battery Mode
95%
94%
 
System Display 
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
DC Voltage
Back up time(1/2 Load)
12V 7Ah
4 hours to 90% capacity
1.5A
72VDC
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400**
SNMP**
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
Dimension, WxDxH mm
Net Weight Kgs(lbs)
190 X 421 X 318
25.8 (57lbs)
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40°C, 20 to 95% humidity (non-condensing)
<50dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
* NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
** For optional features
***Product specifications are subject to change without further notice
 
 
ModelMX 3k
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
3000VA
220V, 230V, 240V, 1Ø 2Wires
40Hz~70Hz
160-300 VAC at 100% load, 110-300 VAC at 50% load
>99%
≤3%
 
Ouput 
Output Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
3000W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires
50/60 Hz +/-0.1Hz
0 ms
Online double conversion design
Pure Sinewave
≤2% (linear load), ≤4% (non linear load)
3:1
 
Protection 
Overload Protection
Short Circuit Protection
110% for 10min, 130% for 1min, >130% for 3sec
UPS output cut off immediately using input fuse/circuit breaker protection
 
Efficiency 
AC Mode
Battery Mode
95%
94%
 
System Display 
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
DC Voltage
Back up time(1/2 Load)
12V 9Ah
4 hours to 90% capacity
1.5A
72VDC
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400**
SNMP**
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
Dimension, WxDxH mm
Net Weight Kgs(lbs)
190 X 421 X 318
27 (60lbs)
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40°C, 20 to 95% humidity (non-condensing)
<50dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
* NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
** For optional features
***Product specifications are subject to change without further notice
 
 
ModelMX 6k
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
6000VA
220V, 230V, 240V, 1Ø 2Wires
40Hz~70Hz
160-300 VAC at 100% load, 110-300 VAC at 50% load
>99%
≤3%
 
Ouput 
Output Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
6000W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires
50/60 Hz +/-0.2%
0 ms
Online double conversion design
Pure Sinewave
≤3% (linear load), ≤5% (non linear load)
3:1
 
Protection 
Overload Protection
Short Circuit Protection
110% for 10min, 130% for 1min, >130% for 1sec
UPS output cut off immediately using input fuse/circuit breaker protection
 
Efficiency 
AC Mode
Battery Mode
>95%
>94%
 
System Display 
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
DC Voltage
Back up time(1/2 Load)
12V 7Ah
6 hours to 90% capacity
1A
240VDC
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400**
SNMP**
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
Dimension, WxDxH mm
Net Weight Kgs(lbs)
250 x 592 x 576
81 (178.2lbs)
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40°C, 0 to 95% humidity (non-condensing)
<55dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
* NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
** For optional features
***Product specifications are subject to change without further notice
 
 
 
 
ModelMX 10k
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
10000VA
220V, 230V, 240V, 1Ø 2Wires
40Hz~70Hz
160-300 VAC at 100% load, 110-300 VAC at 50% load
>99%
≤3%
 
Ouput 
Output Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
10000W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires
50/60 Hz +/-0.2%
0 ms
Online double conversion design
Pure Sinewave
≤3% (linear load), ≤5% (non linear load)
3:1
 
Protection 
Overload Protection
Short Circuit Protection
110% for 10min, 130% for 1min, >130% for 1sec
UPS output cut off immediately using input fuse/circuit breaker protection
 
Efficiency 
AC Mode
Battery Mode
>96%
>95%
 
System Display 
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
DC Voltage
Back up time(1/2 Load)
12V 9Ah
6 hours to 90% capacity
1A
240VDC
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400**
SNMP**
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
Dimension, WxDxH mm
Net Weight Kgs(lbs)
250 x 592 x 576
83 (182.6lbs)
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40°C, 0 to 95% humidity (non-condensing)
<58dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
* NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
** For optional features
***Product specifications are subject to change without further notice