MX33 10~40k

The MX33 UPS is a 3-phase In/Out online double conversion UPS available from 10kVA to 40kVA with an output power factor 1. It is designed to provide ultimate performance in power protection and redundancy for critical systems requiring high power availability. The MX33 series has USB and RS-232 communication ports as standard, with a built-in intelligent slot for optional protocol converters (e.g. SNMP…)


Best Suited for: Banking, financial and insurance, server rooms, data centers, education, healthcare, government.


Description
  • True Online Double Conversion Design
  • Pure Sine Wave Output
  • Fully Digitized Microprocessor Control
  • DSP Technology
  • Output Power Factor 1
  • Active Input Power Factor Correction (PFC 0.99)
  • 50/60 Hz Frequency Converter
  • Wide Input Voltage Range
  • Cold Start Function (DC Power On)
  • Advanced Battery Management (ABM Technology)
  • Automatic Diagnostics & Battery Check
  • High Overload Capability and Enhanced Short Circuit Protection
  • Eco Mode For Energy Saving
  • Isolation Transformer*
  • Programmable Power Management Outlets
  • Multi-Function LCD Display

 * Optional Features

DOCUMENTS & DOWNLOADS

ModelMX 10K 33
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
10000VA
380V, 400V, 415V (selectable), 3Φ4Wires
40~70Hz
176-276 VAC at 100% load, 110-300 VAC at 50% load
>99%
<3%
 
Output 
Output Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
10000W

380V, 400V, 415V +/-1% (selectable output voltage), 3Ø4Wires

50/60 Hz +/-1%
0 ms
Online double conversion design
Pure Sinewave
≤1% (linear load), ≤4% (non linear load)
3:1
 
Efficiency 
AC Mode
Battery Mode
96.5%
95.5%
 
Protection 
Overload Protection
Short Circuit Protection
110% for 60min, 125% for 10min, 150% for 1min, >150% for 400ms
UPS output cut off immediately using input fuse/circuit breaker protection
 
System Display 
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
Battery number
Back up time(1/2 Load)
12V 9Ah 
9 hours to 90% capacity
1A ~ 12A (adjustable)
(10+10) x1 string
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400**
SNMP**
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
W x D x H mm
Net Weight Kgs(lbs)
250 x 630 x 826
124 (273.3lbs)
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40ºC, 0 to 95% humidity (non-condensing)
<60dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
*When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
** For optional features
***Product specifications are subject to change without further notice
 
 
ModelMX 15K 33
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
15000VA
380V, 400V, 415V (selectable), 3Φ4Wires
40~70Hz
176-276 VAC at 100% load, 110-300 VAC at 50% load
>99%
<3%
 
Output 
Output Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
15000W

380V, 400V, 415V +/-1% (selectable output voltage), 3Ø4Wires

50/60 Hz +/-1%
0 ms
Online double conversion design
Pure Sinewave
≤1% (linear load), ≤4% (non linear load)
3:1
 
Efficiency 
AC Mode
Battery Mode
96.5%
95.5%
 
Protection 
Overload Protection
Short Circuit Protection
110% for 60min, 125% for 10min, 150% for 1min, >150% for 400ms
UPS output cut off immediately using input fuse/circuit breaker protection
 
System Display 
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
Battery number
Back up time(1/2 Load)
12V 9Ah 
9 hours to 90% capacity
1A ~ 12A (adjustable)
(16+16) x1 string
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400**
SNMP**
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
W x D x H mm
Net Weight Kgs(lbs)
250 x 630 x 826
139 (306.4lbs)
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40ºC, 0 to 95% humidity (non-condensing)
<605dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
*When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
** For optional features
***Product specifications are subject to change without further notice
ModelMX 20K 33
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
20000VA
380V, 400V, 415V (selectable), 3Φ4Wires
40~70Hz
176-276 VAC at 100% load, 110-300 VAC at 50% load
>99%
<3%
 
Output 
Output Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
20000W

380V, 400V, 415V +/-1% (selectable output voltage), 3Ø4Wires

50/60 Hz +/-1%
0 ms
Online double conversion design
Pure Sinewave
≤1% (linear load), ≤4% (non linear load)
3:1
 
Efficiency 
AC Mode
Battery Mode
96.5%
95.5%
 
Protection 
Overload Protection
Short Circuit Protection
110% for 60min, 125% for 10min, 150% for 1min, >150% for 400ms
UPS output cut off immediately using input fuse/circuit breaker protection
 
System Display 
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
Battery number
Back up time(1/2 Load)
12V 9Ah 
9 hours to 90% capacity
1A ~ 12A (adjustable)
(16+16) x1 string
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400**
SNMP**
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
W x D x H mm
Net Weight Kgs(lbs)
250 x 630 x 826
139 (306.4lbs)
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40ºC, 0 to 95% humidity (non-condensing)
<60dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
*When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
** For optional features
***Product specifications are subject to change without further notice
 
 
ModelMX 30K 33
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
30000VA
380V, 400V, 415V (selectable), 3Φ4Wires
40~70Hz
176-276 VAC at 100% load, 110-300 VAC at 50% load
>99%
<3%
 
Output 
Output Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
30000W

380V, 400V, 415V +/-1% (selectable output voltage), 3Ø4Wires

50/60 Hz +/-1%
0 ms
Online double conversion design
Pure Sinewave
≤1% (linear load), ≤4% (non linear load)
3:1
 
Efficiency 
AC Mode
Battery Mode
96.5%
95.5%
 
Protection 
Overload Protection
Short Circuit Protection
110% for 60min, 125% for 10min, 150% for 1min, >150% for 400ms
UPS output cut off immediately using input fuse/circuit breaker protection
 
System Display 
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
Battery number
Back up time(1/2 Load)
12V 7Ah 
9 hours to 90% capacity
1A ~ 12A (adjustable)
(16+16) x2 strings
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400**
SNMP**
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
W x D x H mm
Net Weight kgs(lbs)
300 x 815 x 1000
225 (496lbs)
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40ºC, 0 to 95% humidity (non-condensing)
<63dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
*When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
** For optional features
***Product specifications are subject to change without further notice
ModelMX 40K 33
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
40000VA
380V, 400V, 415V (selectable), 3Φ4Wires
40~70Hz
176-276 VAC at 100% load, 110-300 VAC at 50% load
>99%
<3%
 
Output 
Output Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
40000W

380V, 400V, 415V +/-1% (selectable output voltage), 3Ø4Wires

50/60 Hz +/-1%
0 ms
Online double conversion design
Pure Sinewave
≤1% (linear load), ≤4% (non linear load)
3:1
 
Efficiency 
AC Mode
Battery Mode
96.5%
95.5%
 
Protection 
Overload Protection
Short Circuit Protection
110% for 60min, 125% for 10min, 150% for 1min, >150% for 400ms
UPS output cut off immediately using input fuse/circuit breaker protection
 
System Display 
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
Battery number
Back up time(1/2 Load)
12V 9Ah 
9 hours to 90% capacity
1A ~ 16A (adjustable)
(16+16) x2 strings
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400**
SNMP**
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
W x D x H mm
Net Weight Kgs(lbs)
300 x 815 x 1000
250 (551.1lbs)
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40ºC, 0 to 95% humidity (non-condensing)
<63dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
*When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
** For optional features
***Product specifications are subject to change without further notice