MXRM 1~10K

The MXRM UPS is an online double conversion UPS available from 1kVA to 10kVA with an output power factor 1. It is designed for use within rack-based enclosures. It provides continuous utility power protection for critical system installation. The MXRM series has USB and RS-232 communication ports as standard, with a built-in intelligent slot for optional protocol converters (e.g. SNMP…)


Best Suited for: Banking, data center, networking wokstations, control systems, video surveillance systems.


DOCUMENTS & DOWNLOADS

DOCUMENTS & DOWNLOADS

DOCUMENTS & DOWNLOADS

Description
  • True Online Double Conversion Design
  • Pure Sine Wave Output
  • Fully Digitized Microprocessor Control
  • DSP Technology
  • Output Power Factor 1
  • Active Input Power Factor Correction (PFC 0.99)
  • 50/60 Hz Frequency Converter
  • Wide Input Voltage Range
  • Cold Start Function (DC Power On)
  • Advanced Battery Management (ABM Technology)
  • Automatic Diagnostics & Battery Check
  • High Overload Capability and Enhanced Short Circuit Protection
  • Eco Mode For Energy Saving
  • Isolation Transformer*
  • Programmable Power Management Outlets
  • Multi-Function LCD Display

 * Optional Features

DOCUMENTS & DOWNLOADS

ModelMXRM 1k
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
1000 VA
220V, 230V, 240V, 1Ø 2Wires
40 to 70 Hz
176-300 VAC at 100% load, 110-300 VAC at 50% load
>99%
≤3%
 
Output 
Active Power cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
1000W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires
50/60 Hz +/-0.1%
0 ms
Online double conversion design
Pure Sinewave
≤2% (linear load), ≤4% (non linear load)
3:1
 
Efficiency 
AC Mode
Battery Mode
95%
93%
 
Protection 
Overload Protection
Short Circuit Protection
110% for 10min, 130% for 1min, >130% for 3sec
UPS output cut off immediately using input fuse/circuit breaker protection
 
System Display 
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously beeping
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
DC Voltage
Extended Back up time
12V 7Ah
4 hours to 90% capacity
1.5A
36 VDC
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400**
SNMP**
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
W x D x H mm
Net Weight Kgs
438x410x88 [2U]
14.2
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40°C, 20 to 95% humidity (non-condensing)
<50dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22,
EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick

*In LV system, only 12V/7Ah x 3 for 1K model and 12V/7Ah x 6 for 3K model are available.
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
NOTE 3: For Long run models (6kVA~10kVA), When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20
** For optional features
***Product specifications are subject to change without further notice
 
 
ModelMXRM 2k
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
2000 VA
220V, 230V, 240V, 1Ø 2Wires
40 to 70 Hz
176-300 VAC at 100% load, 110-300 VAC at 50% load
>99%
≤3%
 
Output 
Active Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
2000W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires
50/60 Hz +/-0.1%
0 ms
Online double conversion design
Pure Sinewave
≤2% (linear load), ≤4% (non linear load)
3:1
 
Efficiency 
AC Mode
Battery Mode
95%
94%
 
Protection 
Overload Protection
Short Circuit Protection
110% for 10min, 130% for 1min, >130% for 3sec
UPS output cut off immediately using input fuse/circuit breaker protection
 
System Display 
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
DC Voltage
Extended Back up time
12V 7Ah
4 hours to 90% capacity
1.5A
72 VDC
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400¹
SNMP¹
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
W x D x H mm
Net Weight Kgs
438x630x88 [2U]
26.9
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40°C, 20 to 95% humidity (non-condensing)
<50dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22,
EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick

*In LV system, only 12V/7Ah x 3 for 1K model and 12V/7Ah x 6 for 3K model are available.
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
NOTE 3: For Long run models (6kVA~10kVA), When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20
** For optional features
***Product specifications are subject to change without further notice
ModelMXRM 3k
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
3000 VA
220V, 230V, 240V, 1Ø 2Wires
40 to 70 Hz
176-300 VAC at 100% load, 110-300 VAC at 50% load
>99%
≤3%
 
Output 
Active Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
3000W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires
50/60 Hz +/-0.1%
0 ms
Online double conversion design
Pure Sinewave
≤2% (linear load), ≤4% (non linear load)
3:1
 
Efficiency 
AC Mode
Battery Mode
95%
94%
 
Protection 
Overload Protection
Short Circuit Protection
110% for 10min, 130% for 1min, >130% for 3sec
UPS output cut off immediately using input fuse/circuit breaker protection
 
System Display 
LCD indicators
UPS Status, Load level, Battery level, Input/Output voltage, Discharge time,and Fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
DC Voltage
Extended Back up time
12V 9Ah
4 hours to 90% capacity
1.5A
72VDC
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400¹
SNMP¹
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
W x D x H mm
Net Weight Kgs
438x630x88
27.4
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40°C, 20 to 95% humidity (non-condensing)
<50dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22,
EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick

*In LV system, only 12V/7Ah x 3 for 1K model and 12V/7Ah x 6 for 3K model are available.
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
NOTE 3: For Long run models (6kVA~10kVA), When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20
** For optional features
***Product specifications are subject to change without further notice
 
 
ModelMXRM 6k
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
6000 VA
220V, 230V, 240V, 1Ø 2Wires
40 to 70 Hz
176-300 VAC at 100% load, 110-300 VAC at 50% load
>99%
≤3%
 
Output 
Active Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
10000W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires
50/60 Hz +/-0.1%
0 ms
Online double conversion design
Pure Sinewave
≤3% (linear load), ≤5% (non linear load)
3:1
 
Efficiency 
AC Mode
Battery Mode
>95%
>94%
 
Protection 
Overload Protection
Short Circuit Protection
110% for 10min, 130% for 1min, >130% for 1sec
UPS output cut off immediately using input fuse/circuit breaker protection
 
System Display 
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
DC Voltage
Extended Back up time
12V 7Ah
6 hours to 90% capacity
2A
240VDC
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400¹
SNMP¹
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
W x D x H mm
Net Weight Kgs
438x580x133
17
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40°C, 0 to 95% humidity (non-condensing)
<55dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22,
EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick

*In LV system, only 12V/7Ah x 3 for 1K model and 12V/7Ah x 6 for 3K model are available.
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
NOTE 3: For Long run models (6kVA~10kVA), When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20
** For optional features
***Product specifications are subject to change without further notice
 
 
ModelMXRM 10k
 
Input 
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
10000 VA
220V, 230V, 240V, 1Ø 2Wires
40 to 70 Hz
176-300 VAC at 100% load, 110-300 VAC at 50% load
>99%
≤3%
 
Output 
Active Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
10000W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires
50/60 Hz +/-0.1%
0 ms
Online double conversion design
Pure Sinewave
≤3% (linear load), ≤5% (non linear load)
3:1
 
Efficiency 
AC Mode
Battery Mode
>96%
>95%
 
Protection 
Overload Protection
Short Circuit Protection
110% for 10min, 130% for 1min, >130% for 1sec
UPS output cut off immediately using input fuse/circuit breaker protection
 
System Display 
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
 
Alarm 
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
 
Battery 
Battery Type
Typical Recharge Time
Charging Current
DC Voltage
Extended Back up time
12V 9Ah
6 hours to 90% capacity
2A
240VDC
10~15 min depending on load
 
Communication 
USB, RS-232, AS-400¹
SNMP¹
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
 
Physical 
W x D x H mm
Net Weight Kgs
438x668x133
20
 
Environment 
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40°C, 0 to 95% humidity (non-condensing)
<58dBA at 1 Meter
 
Standards & Certifications 
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22,
EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick

*In LV system, only 12V/7Ah x 3 for 1K model and 12V/7Ah x 6 for 3K model are available.
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
NOTE 3: For Long run models (6kVA~10kVA), When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20
** For optional features