Input | | Rating | Voltage | Frequency | Voltage range | Power Factor | THDi |
| 15000VA | 380V, 400V, 415V (selectable) , 3Φ4wires | 40 to 70 Hz | 305-478 VAC at 100% load, 190-520 VAC at 50% load | >99% | <3% |
|
|
|
Output | | Active Power @ PF=1 | Voltage (on battery) | Frequency (on battery) | Transfer Time | UPS Design Technology | Output Wave Form | Total Harmonic distortion (THD) | Crest Factor |
| 15000W | 220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires | 50/60 Hz +/-0.1% | 0 ms | Online double conversion design | Pure Sinewave | ≤2% (linear load), ≤5% (non linear load) | 3:1 |
|
|
|
|
|
Protection | | Overload Protection | Short Circuit Protection |
| 110% for 10min, 130% for 1min, >130% for 3sec | UPS output cut off immediately using input fuse/circuit breaker protection |
|
|
|
System Display | | | UPS status, load level, battery level, input/output voltage, discharge time and fault indicators |
|
|
|
Alarm | | Battery Mode | Low Battery | Overload | Fault |
| Sounding every 4 seconds | Sounding every second | Sounding twice every second | Continuously sounding |
|
|
|
Battery | | Battery Type | Typical Recharge Time | Charging Current | Battery number | Back up time(1/2 Load) |
| 12V 9Ah | 9 hours to 90% capacity | 2A | 20 x2 strings | 10~15 min depending on load |
|
|
|
Communication | | USB, RS-232, AS-400** | SNMP** | Compatibility |
| Interface with power management software | Power Management from SNMP manager and web browser | Supports Windows family, Linux, Unix and Mac |
|
|
|
Physical | | W x D x H mm | Net Weight Kgs(lbs) |
| UPS: 438 X 668 x 266[6U] Battery Pack:438 x 580 x 133[3U] x 2 pcs | UPS: 45 (99lbs) Battery: 63 (138.6lbs)x2pcs |
|
|
|
Environment | | Ambient operation | Audible noise |
| Maximum elevation at 1000m, 0 to 40°C, 0 to 95% humidity (non-condensing) | <65dBA at 1 Meter |
|
|
|
Standards & Certifications | | Performance | Safety | EMC (EMS / EMI) | Design, production, and services | Environment | Marking & Certifications |
| EN50091-3/IEC 62040-3 | UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950 | IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A EN 55022/B,FCC 47 part 15 - Subpart B - | ISO 9001 | ISO 14001 certified company | CE, TUV/GS, UL, cUL, c-Tick |
|
|
*When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20 NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC. NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m. ** For optional features ***Product specifications are subject to change without further notice |