| Input | | | Rating | | Voltage | | Frequency | | Voltage range | | Power Factor | | THDi |
| | 10000VA | | 220V, 230V, 240V, 1Ø 2Wires | | 40~70Hz | | 176-300 VAC at 100% load, 110-300 VAC at 50% load | | >99% | | <5% |
|
|
| |
| Ouput | | | Active Power @ PF=0.9 | | Voltage (on battery) | | Frequency (on battery) | | Transfer Time | | Efficiency | | UPS Design Technology | | Output Wave Form | | Total Harmonic distortion (THD) | | Crest Factor |
| | 9000W | | 220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires | | 50/60 Hz +/-0.2% | | 0 ms | | >95% | | Online double conversion design | | Pure Sinewave | | ≤3% (linear load), ≤5% (non linear load) | | 3:1 |
|
|
| |
| Protection | | | Overload Protection | | Short Circuit Protection |
| | 110% for 30min, 130% for 5min, >130% for 10sec | | UPS output cut off immediately using input fuse/circuit breaker protection |
|
|
| |
| System Display | | | | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
|
|
| |
| Alarm | | | Battery mode | | Low battery | | Overload | | Fault |
| | Sounding every 4 second | | Sounding every second | | Sounding twice every second | | Continuously sounding |
|
|
| |
| Battery | | | Battery Type | | Typical Recharge Time | | DC Voltage | | Charging Current | | Back up time(1/2 Load) |
| | 12V 9Ah | | 5 hours to 90% capacity | | 192VDC | | 1-2A (adjustable) | | 10~15 min depending on load |
|
|
| |
| Communication | | | USB or RS-232 | | SNMP* | | Compatibility |
| | Interface with power management software | | Power Management from SNMP manager and web browser | | Supports Windows family, Linux, Unix and Mac |
|
|
| |
| Physical | | | W x D x H mm | | Net Weight Kgs(lbs) |
|
| | 190x442x688mm | | 66kg(145lbs) |
|
|
| |
| Environment | | | Operating Temperature | | Storage Temperature | | Altitude | | Audible noise | | Relative Humidity |
| | 0 - 40 °C / 32 ~ 104°F | | -20 ~ 50°C / -4 ~ 122°F | | 1,500 meters max | | <58dBA at 1 Meter | | 0 ~ 95% humidity, non-condensing |
|
|
| |
| Standards & Certifications | | | Performance | | Safety | | EMC (EMS / EMI) | | Design, production, & services | | Environment | | Marking & Certifications |
| | EN50091-3/IEC 62040-3 | | UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950 | | IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B - | | ISO 9001 | | ISO 14001 certified company | | CE, TUV/GS, UL, cUL, c-Tick |
|
|
| |
* For optional features ***Product specifications are subject to change without further notice |